Arthromot S-4
2SKU:
N/A
Brand:
ARTROMOT
- Facilidades de pago
- 14-días para retornar
- Entrega: 1-2 Días
The continuous passive movement machine Arthromot-S4 is the result of 30 years of experience in the shoulder CPM device business and more than 3 years of dedicated engineering, manufactured in Germany.
Backed by three integrated engines, the new global DJO model admits the following movements:
- Anteversion & AMP; retroversion
- Adduction & amp; kidnapping
- Internal & amp; external rotation
- Extension & amp; flexion (elevation) with extended or flexed arm
- The combination of these axes of movement allows anatomically correct PNF movements, as well as the tested "wave". o Ondulation exercise.
- Combined with the proven and tested characteristics, such as the patient chip card and the resistant design, the new arthromot-S4 has even more therapy options to offer.
- Manual controller with touch screen and motor controls for direct programming of movement ranges, with a clear presentation and descriptive icons
- 3 engines for all movement axes: anteversion and AMP; retroversion, adduction and AMP; internal abduction and AMP; external rotation, extension & AMP; flexion (elevation) with extended or flexed arm
- User guide for easy conversion of the device for the treatment of right or left shoulder * Adaptive load investment (load reversal function for patient safety / spasms protection), automatically adjusts and sensitivity can be adjusted
- Reinforced support with adjustable width and height
Technical specifications:
Dimensions for transport: | Box 1: 81 × 68 × 56 cm, 19 kg Box 2: 111 × 39 × 12 cm, 11 kg Box 3: 69 × 54 × 18 cm, 9 kg |
Electrical security class: | II |
MDD: | II a |
IP Class: | IP21 |
Pulse frequency: | 1 to 150 Hz |
MDD: | Class iia |
IP Class: | IP22 |
Applied part: | Type b |
Weight: | 28 kg |
Dimensions: | 166 × 100 × 160 cm |
Adduction/abduction: | 0 ° / 30 ° / 160 ° |
Internal/external rotation: | 110 ° / 0 ° / 10 ° |
Elevation: | 0 ° / 30 ° / 160 ° |
Internal / external rotation: | 90 ° / 0 ° / 90 ° |
Isolation: | Allows separate exercises in the 3 movement directions within a single treatment |
Oscillation: | Higher movement rate in the ROM phase |
PNF: | Movements following the PNF pattern |
Stretch: | For a gradual and uniform increase in the amplitude of movement |
Motion: | Undulating movements that resemble a figure of side eight |
Applied part: | Type b |
Goniometer precision: | ±2° |
Max. Continuous load in movement element: | 13 kg |
Max. Continuous load in the seat: | 175 kg |
Patient height: | approx. 120 to 210 cm |
Adaptive load investment: | 5-100% of the tolerance range of the trigger threshold (reverse function in patient safety / spasm protection) |
Cycles: | 5-20, adjustment of isolation, oscillation and stretch repetitions |
Device settings: | Basic configuration adjustment (for example, date, time or language) |
Ondulation address: | Adjustment of the movement of the movement in Wave mode (undulation) |
Visualization mode: | Alternate between detailed view and standard view |
Headrest: | For optimal and comfortable patient placement |
Blocking functions: | Block individual functions, avoid accidental setting changes in established parameters and facilitate the operation |
Motor A, B and C ON / OFF: | Isolated movements, exclusively abduction / adduction, anteversion / retroversion or internal / external rotation |
Motor control: | For direct movement rank input |
New patient: | Activates the default setting for new patients |
Patient chip card: | Stores the patient's specific therapy parameters |
Pauses: | 0-30 second |
Service menu: | For service technicians |
Lateral conversion: | For an easy and user -guided conversion between the right and left shoulder configuration |
Waiting time: | Inactive units adjustment parked in insulation mode |
Therapy documentation: | Graphical presentation of the general treatment cycle |
Timer: | 1-59 min., 1-12 hours / continuous operation |
Total therapy time: | Added sum of all therapy sessions |
Transport position: | Move the engines to the transport position |
Heating protocol | Gradual progression to the maximum movement amplitude phase |
To install this Web App in your iPhone/iPad press and then Add to Home Screen.